The wooden timber house consists of:
kitchen - 6,95 ì2; bedroom 1 - 10,64 ì2;
bedroom 2 - 10,64 ì2; drawing-room - 18,33 ì2;
WC - 6,10 ì2; |
|
|
|
|
|
 |
|
|
|
|
|
 |
|
|
|
|
|
 |
|
|
|
|
|
The wooden timber house consists of:
kitchen - 7,90 ì2; bedroom 1 - 10,50 ì2;
dining-room - 8,60 ì2; bedroom 2 - 10,20 ì2;
drawing-room - 15,60 ì2; WC - 2,60 ì2; |
|
|
|
|
|
 |
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
Catalog , wooden house > Houses > Up to
80 m2 | sk 62 |
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
SELLER OFFER
for One-Storey Prefabricated Structure,
Model SK 62
(Total built area 62 ì2)
Building construction:
Exterior Panels - 120-mm thick, faced with KNAUF gypsum fiberboard,
insulation - mineral wool (density 55-65 kg/m3, coefficient of thermal
conductivity W/MK - 0.034), lined with wooden paneling from the
outside.
Interior Panels - 100-mm thick, faced with KNAUF gypsum
fiberboard, insulation - 80-mm mineral wool, ceiling elements -
94-mm thick - KNAUF gypsum fiberboard - 80-mm mineral wool - fiberboard.
Roof - triangular wooden trusses, a set of joists for Ondulin
and front boards. Ceiling, terrace and eaves with nailed wooden
paneling.
Millwork - windows of the pasted together type (unglazed)
or glass package, solid front door, interior doors - compacted with
fiberboard, a set of Bulgarian facing.
Technical Parameters:
- Heat transfer coefficient - 0.105 W/m2
- Difference between decibel levels - Eb=-60 dB
- Fire resistance - 30 min
- Snow loading - 2000 N/m2
- Wind loading - 1000 N/m2
- Combined snow and wind loading of the end panel - 4060 N/m2
- Normal life - 50 years
- The prefabricated houses are up to the requirements of the Specialized
Standards OH-0372492-81 and OH-0372493-81.
|
|
|
|
|
|
|
|
|
|
|
up
 |
|
|
|
|
|
|
|
|
|
Catalog , wooden house > Houses > Up to
80 m2 | sk 74 |
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
SELLER OFFER
for One-Storey Prefabricated Structure,
Model SK 74
Building construction:
The walls and ceilings are a set of unified, "sandwich"
type elements of a 1200-2400-100 mm basic module.
- Exterior walls: gypsum fiberboard - mineral wool - gypsum fiberboard.
- Interior walls: gypsum fiberboard - mineral wool - gypsum fiberboard.
- Ceiling elements: gypsum fiberboard - mineral wool - fiberboard.
Millwork:
Windows - of the glass package type, varnished.
Jalousie - wooden shutters.
Doors - front and interior - solid, made of pine.
Roof Structure:
The roof is a hip roof - a wooden structure of beams and joists
for Ondulin or tiles completed with plastic gutters and accessories.
The exterior walls are coated with a mineral waterproof coat, and
the interior walls with latex.
The water supply and sewerage are fabricated up to plugs. The electric
installation - up to brackets.
Technical Parameters:
- Heat transfer coefficient - 0.105 W/m2
- Difference between decibel levels - Eb=-60 dB
- Fire resistance - 30 min
- Snow loading - 2000 N/m2
- Wind loading - 1000 N/m2
- Combined snow and wind loading of the end panel - 4060 N/m2
- Normal life - 50 years
- The prefabricated houses are up to the requirements of the Specialized
Standards OH-0372492-81 and OH-0372493-81.
|
|
|
|
|
up
 |
|
|
|
|
|
|
|
|
|
|
The elements and construction of the wooden timber house will be transported at the place of the erection. Our company has
a dispose of specialists, which can build the house construction. |
|
|
|
|
|